Deep Sea - Auto Start (Start-O-Matic)

Blades Power Generation We are specialist manufactures of power generation, ATS / AMF Panels Of both Manual & Automatic, We also build Bespoke Units please call one of our sales team for assistance.
Manufacturer part number: ASLS1
Manufacturer: Blades Power Generation
£553.07 excl tax

Start O Matic, Load sensing Panels

These are generally used on smaller sized generating sets, up to around 18 – 20 KVA and configured for single phase operation. The typical size would be around 10kVA. This size is more than sufficient to run a modern house hold consisting of washing machines, televisions, microwaves etc.

Typical applications are remote buildings away from the mains network, for example farms and isolated properties.

The load sensing engine control panel includes a load sensing control facility. This continually monitors the connected load waiting for an appliance to be switched on ( load must be at least 60w bulb). Once an item is switched on the load sense panel will control the starting of the generator by enabling the pre-heat, fuel and starter control relay . Whilst the generator is running the load sense panel will monitor the engine and alternator, safely stopping the generator should a fault condition occur.

When all appliance are switched off the load sense panel will stop the generator after a cool down period.

Start O Matic, Load sensing Panels

These are generally used on smaller sized generating sets, up to around 18 – 20 KVA and configured for single phase operation. The typical size would be around 10kVA. This size is more than sufficient to run a modern house hold consisting of washing machines, televisions, microwaves etc.

Typical applications are remote buildings away from the mains network, for example farms and isolated properties.

The load sensing engine control panel includes a load sensing control facility. This continually monitors the connected load waiting for an appliance to be switched on ( load must be at least 60w bulb). Once an item is switched on the load sense panel will control the starting of the generator by enabling the pre-heat, fuel and starter control relay . Whilst the generator is running the load sense panel will monitor the engine and alternator, safely stopping the generator should a fault condition occur.

When all appliance are switched off the load sense panel will stop the generator after a cool down period.

Products specifications
Component Manufacture Deep Sea
Requirement Industrial 3 Phase + N 415v
Requirement Residential Single Phase 240v
Requirement 12v Dc Control