Search
Filters
Close
Here At Blades Power, we have a full range of Automatic Transfer Switches Manufactured In House Using . They are built to the highest standard, all panels are fully tested and issued with a serial No. Every Panel is dispatched with a copy of the Electrical Schematic and test report + All Datasheets for each electrical internal part.
Manufacturer part number: ABB355MG
Delivery date: 3-5 Working Days
Manufacturer: Blades Power Generation
£863.00 incl tax

Product Specification for Mains to Generator Operation 55 Amp ABB Single Phase

1) 2 x 4 Pole AC1 Rated Contactors, Electrically & Mechanically Interlocked “break before make”
2) Phase Failure Relay For Mains Monitoring
3) Mains (Utility) – Delay On Load Timer ( Pre Set 10sec )( Adjustable 0.3 Sec – 30 Hrs )
4) Generator – Delay On Load Timer ( Pre Set 30sec ) ( Adjustable 0.3 Sec – 30 Hrs )
5) 10 Amp Mains L1- 240v A/c Auxiliary Supply For ( B/Charger / W/Heater)
6) Set Rated Fuses for control circuit
7) Mains On Load Volt Free Contact ( For BMS )
8) Generator On Load Volt Free Contact ( For BMS )
9) Set Volt Free Contacts for remote Start Facility ( 2 Wire Start )
10) Mounted Within an all Steel Enclosure, with Top & Bottom Removable Gland Plates.
IP65 Rated RAL7032 With Lockable Door 1 Key Supplied & Wall Mounting Brackets


LED Indication
Mains Available (GREEN), Mains On Load (RED)
Generator Available (GREEN), Generator On Load (AMBER)

 

We also have Contactor Options from

LOVATO –

TERASAKI –

ICG –

If you require different manufacture, please contact and we will add these to our range.

 

ADDITIONAL OPTIONS IF REQUIRED- IF NOT SHOWN PLEASE CALL FOR PRICING

Auto Test Facility Switch With 2 Keys, Primary Mains Failure simulation

Deep-Sea - 12v & 24V Dc Battery Charger

Modbus RS485 Connections Available

Digital Metering For Voltage / Current  - Including Current Transformers

Product Specification for Mains to Generator Operation 55 Amp ABB Single Phase

1) 2 x 4 Pole AC1 Rated Contactors, Electrically & Mechanically Interlocked “break before make”
2) Phase Failure Relay For Mains Monitoring
3) Mains (Utility) – Delay On Load Timer ( Pre Set 10sec )( Adjustable 0.3 Sec – 30 Hrs )
4) Generator – Delay On Load Timer ( Pre Set 30sec ) ( Adjustable 0.3 Sec – 30 Hrs )
5) 10 Amp Mains L1- 240v A/c Auxiliary Supply For ( B/Charger / W/Heater)
6) Set Rated Fuses for control circuit
7) Mains On Load Volt Free Contact ( For BMS )
8) Generator On Load Volt Free Contact ( For BMS )
9) Set Volt Free Contacts for remote Start Facility ( 2 Wire Start )
10) Mounted Within an all Steel Enclosure, with Top & Bottom Removable Gland Plates.
IP65 Rated RAL7032 With Lockable Door 1 Key Supplied & Wall Mounting Brackets


LED Indication
Mains Available (GREEN), Mains On Load (RED)
Generator Available (GREEN), Generator On Load (AMBER)

 

We also have Contactor Options from

LOVATO –

TERASAKI –

ICG –

If you require different manufacture, please contact and we will add these to our range.

 

ADDITIONAL OPTIONS IF REQUIRED- IF NOT SHOWN PLEASE CALL FOR PRICING

Auto Test Facility Switch With 2 Keys, Primary Mains Failure simulation

Deep-Sea - 12v & 24V Dc Battery Charger

Modbus RS485 Connections Available

Digital Metering For Voltage / Current  - Including Current Transformers

Products specifications
Component Manufacture ABB
Amp Rating 55 Amp
Requirement Residential Single Phase 240v
IP65 All Steel Enclosure 400 High 400 Wide 200 Deep
Products specifications
Component Manufacture ABB
Amp Rating 55 Amp
Requirement Residential Single Phase 240v
IP65 All Steel Enclosure 400 High 400 Wide 200 Deep